Framework
-Industrial facilities in demolition with buried hydrocarbons tanks.
-Heterogeneous sedimentary substrate.
-Work must be fast for next new builiding.
Parameters to be treated
-Affection by heavy hydrocarbons C21-C35, in the unsaturated zone (500 m2).
Treatment
-Selective excavation of hydrocarbons polluted soils.
-Temporary storage on conditioned area.
-Characterization and management to controlled landfill.
Results obtained
-Management of 534 t to Clase III controlled landfill.
-Management of 2159 t to Clase II controlled landfill.
Duration
-3 months: May 2015 – July 2015